Brochure
EvoDry 6H 2.0 is designed for smaller spaces, especially those that are used less frequently. The desiccant dehumidifier is designed for user-friendly operation, high durability and easy maintenance. It is equipped with an electronic hygrostat, has a low weight and low noise level and is easy to install. Electrical connection is via cable with plug (approx. 2 m).
The dehumidifier is well suited for unheated or periodically cold environments with a risk of moisture damage, such as boats, caravans, motorhomes, storage rooms, sheds, warehouses, cold rooms, containers, covered car trailers, basements, tack rooms and holiday homes. The unit can also be supplemented with accessories such as a wall bracket or process air outlet.
The following are included:
- Acetec EvoDry 6H 2.0
- Wet gas hose Ø 50 mm, length 1.5 m
- Outlet plate with precipitation protection

EvoDry dehumidifiers are manufactured and quality assured in Älvsbyn, Sweden.
Typical application areas
- Smaller garage: In unheated garages, EvoDry 6H 2.0 helps keep the air dry and reduces the risk of condensation, rust and stale odours.
- Cellars, storage rooms and sheds: EvoDry 6H 2.0 keeps humidity levels down in smaller unheated spaces where condensation, odours and mould can easily occur.
- Boat: During winter storage or extended downtime, EvoDry 6H 2.0 prevents condensation, odours and mould growth in the cabin and stowage areas.
- Caravans and motorhomes: During downtime, EvoDry 6H 2.0 keeps the interior dry and protects textiles, electronics and fittings from moisture-related damage.
- Container: In smaller containers and storage modules, EvoDry 6H 2.0 reduces the risk of condensation, rust and mould.
More information is available at www.acetec.se. Search for the relevant product (art. no. 20010). EvoDry 6H 2.0 is not intended for crawl spaces or cold attics. For these applications, EvoDry RCF 12 (art. no. 20012) or EvoDry RCF 20 (art. no. 20020) is recommended.
For technical advice or to request a quote, please contact sales@acetec.se
Technical data
| Specification | Value |
|---|---|
| Suitable up to (m³) | 100 |
| Control panel | No, it is not. |
| Wet air flow (m³/h) | 20 |
| Dry air flow rate (m³/h) | 110 |
| Capacity at 20°C/60% RF (l/24h) | 7,4 |
| Sound level (dBA) | 48 |
| Hedging (A) | 10 |
| Power, fan, nom (W) | 25 |
| Power, at dehumidification (W/h) | 530 |
| W x H x D (mm) | 217 / 225 / 307 |
| Weight (kg) | 5,4 |
Capacity diagram
Installation Instructions
Assembly
The dehumidifier is intended for installation indoors or in a weather-protected area only. It must not be installed in environments with aggressive or explosive gases, and must not be exposed to water splashes or submerged in water.
The dehumidifier is placed in the space to be dehumidified or outside using accessories. The wet gas hose (50 mm) is led out of the space being served and connected to the outlet plate mounted on the outside of the wall.
The hole through the outer wall should be approximately 70 mm. A duct or hose can be fitted to the dehumidifier's connector to distribute the dry air in the room. The suction side, where the humid air is drawn in, can also be connected using the accessory. process air blast.
Electrical connection is via cable with plug to earthed socket 1×230 V with its own 10 A slow-blow fuse.
Manual
Electronic hygrostat
The dehumidifier has a built-in electronic hygrostat with settings via a graduated scale located at the intake filter. There you can easily set the desired setpoint. When the humidity exceeds the set value, dehumidification starts automatically. For continuous operation, the knob can be set to the position. "ON".
Fan operating modes
Various operating modes for the dehumidifier fan can be set using switches on the circuit board:
- Position 1: Constant fan operation regardless of whether dehumidification is in progress or not. Suitable when you want to maintain constant negative pressure, for example in cases of odour problems.
- Position 2: When the humidity level falls below the set value on the hygrostat and dehumidification is interrupted, the fan also stops. However, the fan starts up for 15 minutes every 4 hours to circulate air in the space and check the humidity level. Suitable for larger spaces where the humidity level can vary in different areas.
- Position 3: When the humidity level falls below the set value on the hygrostat and dehumidification is interrupted, the fan also stops. However, the fan starts for 3 minutes every 12 hours to circulate air in the space and check the humidity level.
How dehumidification works
- Process air: Humid air sucked into the dehumidifier to be dehumidified.
- Wet air: Moisture-saturated weak air stream that removes moisture from the space served.
- Dry air: Dry and slightly heated air dispersed in the served space.
Wiring Diagram
Operation and Maintenance
Care instructions
EvoDry 6H 2.0 requires minimal maintenance. Maintenance is simple and mainly consists of filter replacement and light internal cleaning (vacuuming). This basic maintenance is important for the dehumidifier to function optimally and have a long service life.
Execution
- Pull the plug out of the socket.
- Replace the filter without any tools by grasping the filter and pulling it straight out of the filter holder.
- Vacuum the inside of the dehumidifier. The cover can be opened with a star-shaped screwdriver.
Service interval
- Filter byte: Approximately twice a year, or more often during periods of high load.
- Internal vacuum cleaning: approximately once every two years, or as needed.
Technical Data Sheet
| Specification | Value |
|---|---|
| Terms and conditions of guarantee | AG 20 |
| EC | Yes |
| Dehumidification type | Sorption |
| Working range (°C) | -20 to +40 |
| Suitable up to (m³) | 100 |
| Control equipment | Hygrostat |
| Wet air flow (m³/h) | 20 |
| Wet air blast (mm) | 50 |
| Dry air blast (mm) | 1 × 100 |
| Dry air flow rate (m³/h) | 110 |
| Capacity at 20 °C/60 % RF (l/24h) | 7,4 |
| Capacity up to (l/24h) | 7,4 |
| Sound level (dBA) | 56 |
| Hygrostat setting (%) | 0 to 100 |
| Power, fan, nom (W) | 25 |
| Dehumidification power (W/h) | 530 |
| Connection voltage (V) | 1 × 230 |
| Hedging (A) | 10 |
| IP class | IP21 |
| W x H x D (mm) | 217 / 225 / 307 |
| Weight (kg) | 5,4 |
| Filter class | G4 |
| Coatings / Materials | Magnelis |
| Corrosion class | C4 |