The housing unit EvoAir A60T G2 i Magnelis är en vidareutveckling av vår populära A60T-modell. Aggregatet är utformat för en diskret drift och smidig installation. Med inbyggd ljuddämpning, kanalanslutningar på samma sida och energieffektiv stegmotor utan växellåda, får du en pålitlig ventilation som tar minimalt med plats.
Brochure
Advantages of the programme
- For apartments and houses up to 120 m²
- Rotary heat exchanger with reliable stepper motor
- Comfortable and low noise level
- Supply and exhaust air on the same side (no crossing of ducts)
- Energy class A
- Flexible right/left connection
Full product information is available at www.acetec.se

EvoAir ventilation units are manufactured and quality assured in Älvsbyn, Sweden.
Technical data
| Specification | Value |
|---|---|
| Connection options | Top |
| Flow range (l/s) | 15 to 70 |
| Suitable up to living space (m²) | 120 |
| Control equipment | EvoControl MPO |
| Coatings/Materials | Magnelis |
| Type of heat exchanger | Rotating |
| Placement | Wall |
| W x H x D (mm) | 599 / 532 / 335 |
| Weight (kg) | 39 |
| Duct connection (mm) | 4 x 125, 1 x 125 |
| Fan power (W) | 2 x 85 |
| Connection voltage (V) | 1 x 230 |
For technical advice or to request a quote, please contact sales@acetec.se
Pressure and flow diagrams
Sewer connections

The A60T G2 offers flexible duct connectivity and can be easily configured for both right and left hand installation. The illustrations above show the different connection options. See detailed information under "Installation instructions".
Dimension sketch

| Designation | Dimensions (mm) |
|---|---|
| A | 599 |
| B | 222 |
| C | 88 |
| D | 335 |
| E | 100 |
| F | 532 |
| G | 60 |
| H | 297,5 |
| I | 165 |
| J | 25 |
| K | 125 |
| L | 46 |
See designations in the illustration above.
Complementary cooker hoods

Monolith 600 mm RF

Monolith 600 mm White

392 White 600 mm LED
These functional cooker hoods are adapted for this ventilation unit. They are designed for residential ventilation in houses and flats and are equipped with a control function for the unit. The air flow is regulated via the cooker hood damper. The damper has a timer function that automatically switches off the forcing after 60 minutes or when the knob is reset.
- Article numbers 340167 & 340166: Cooker hoods with control function against the unit, possibility of forcing and timer control of the damper.
- Item number 340036: Pull-out cooker hood for central ventilation with electronic switch, LED lighting and motorised damper. Does not have its own motor and is connected directly to the ventilation system. White front strip included; other colours available as an option.
You can read more about our www.acetec.se
Installation Instructions
Procedure
Installation and commissioning must be carried out by a person with industry expertise to ensure correct operation.
Right or left configuration is determined by how the unit angle is mounted. The unit is attached to the wall using the supplied mounting bracket.
For kitchen installation
For kitchen installations, the unit and cooker hood are installed as separate units, which simplifies the work. The cooker hood is connected to the unit with a 125 mm hose (not included). The electrical connectors are connected on the underside of the unit.
The minimum construction height between the top of the cooker hood and the top of the unit is 590 mm. This mounting method provides more space for duct adaptation above the unit and enables flexible mounting with a lower lifting height.
The supply and exhaust air are on the same side of the unit, which means that the ducts do not need to be crossed when installed in kitchens.
DUT below -20 °C
At design outdoor temperatures (DUT) lower than -20 °C shell preheater (accessory) installed in the A60T G2 for safe operation.
Electricity connection
The unit is internally wired and comes with a cord set. The plug is connected to a grounded socket 1×230 V, 10 A slow-blow fuse. The control panel is connected to the unit via a 5-metre flat cable with quick connectors.
When installing with a cooker hood, connect the hood's electrical connectors to the underside of the unit. Connectors for lighting and control signals are also connected directly to the unit's connections.
Connection cable preheating
The connection cable to the preheater is pre-wired.
Commissioning
When commissioning, air flows must be adjusted so that the exhaust air flow is 10-15% higher than the supply air flow (negative pressure) for safe operation. Applies to all operating modes.
Important to consider when installing
- Installation and commissioning shall be carried out by a person with sufficient professional knowledge to ensure proper functioning.
- If the system is not commissioned immediately, all duct connections should be sealed inside the unit to prevent moist or cold air from entering and causing moisture damage.
- All operating modes shall be adjusted (Spruce, Comfort and convenience and Forcing).
- The control panel should be positioned so that the user has good access and overview in the event of an alarm.
- The user/manager of the installation shall be informed of the location of the control panel and its functions.
- The installer shall hand over the manuals and the guarantee certificate to the user/manager of the installation.
- The product must be registered at www.acetec.se for the guarantee to apply.
- Original filters must be used during the warranty period for the warranty to be valid.
EvoControl MPO
EvoControl MPO offers stable and reliable control via a wired network connection. The system is connected to a cloud-based solution with a responsive design that automatically adapts to the device you are using – whether it is a mobile phone, tablet or computer.
Components
The EvoControl MPO consists of the following:
Display

1.4” OLED display with three physical buttons. LED for visual status indication (see colour codes in technical manual).
Main card

- Fuse 5x20mm, 200mAT, 230VAC
- RJ45 network socket
- Battery CR3225
- USB connector
Included
- 5 m cable 4×0.25 mm² (max. length 25 m)
Installation of the display
The control panel should be installed in a warm, weather-protected and easily accessible space for easy inspection and quick attention to any climate alarms. Avoid placement in humid environments or where condensation may occur.
- Mount the control panel on a flat surface.
- Pull the cable upwards, downwards or straight backwards as required.
- When pulling the cable downwards: unscrew the back cover and turn it over.
- Connect the supplied cable (crossed modular cable) to the connector on the underside of the panel.
- Open the flaps on the front of the control panel and screw the panel to the base.
- Close the hatches again.

Quick Guide EvoControl MPO
Change operating modes
Step 1)
To change the operating mode, select the row and press Enter.
Step 2)
Select new operating mode with Up arrow
and Arrow down
and confirm with Enter.
Adjust air flow
Step 1)
Please select Menu and pressure Enter.
Step 2)
Step down to Preferences and pressure Enter.
Step 3)
Enter authorisation code 6374 (8990 for advanced) and press Enter. Enter one digit at a time using the up arrow key.
and Arrow down
and confirmed by Enter. Confirm the code you have entered by pressing Enter when “-” is selected.

See Step 4 on the next page.
Step 4)
Please select Fan and pressure Enter.
Step 5)
Select the flow you want to adjust and press Enter.
Step 6)
Increase or decrease the value with the Up arrow
or Arrow down
and then press Enter.
Step 7)
Confirm by selecting Save = Yes and pressure Enter.
Repeat steps 5-7 to change the parameters you need.
Pressures Back to access the start menu.
Wiring Diagram
Operation and Maintenance
Before working with the unit
Only authorised personnel should operate and service the unit. This instruction applies to all units and describes operating principles, maintenance, troubleshooting and safety measures. The aim is to ensure a long service life, high operational reliability and energy-efficient operation.
General about the unit
Service intervals and inspection schedule
Carry out servicing at least twice a year or more often at high load. Supplement with intervals for specific components as below:
- Filter byte: every 3-6 months or after a defined number of operating hours.
- Checking seals and mouldings: each service.
- Checking fan bearings and motors: annually.
- Cleaning of rotor or heat exchanger: annually.
- Control of sensors and control systems: annually.
See service procedure (cleaning, dismantling, etc.) on the next page.
Service procedure
- Switch off the power to the unit via fuse or plug before servicing.
- Secure the unit against accidental re-connection during work.
- Wait until all moving parts have come to a complete stop before starting work.
- Use personal protective equipment such as protective gloves and goggles. When working with dust, wear a respirator.
- Mark the unit with a warning sign during servicing.
- Open inspection hatches or panels (e.g. loosen screws with a suitable Allen key).
- Take old filters straight out of their mounts.
- Vacuum the inside and clean surfaces with a mild detergent (avoid strong solvents).
- To facilitate internal cleaning, fans fitted with electrical connectors can be removed from the unit (document electrical connections before dismantling components).
- If necessary, clean the rotor or heat exchanger unit according to the recommended method.
- Check seals, gaskets and mouldings.
- Fit new filters and reassemble components correctly. Original filters can be ordered at www.acetec.se
- Check that everything is secure and close the hatches.
- Reinstall all guards and ensure proper operation before putting the unit into service.
After completion of the service
- Reconnect the power.
- Switch on the unit.
- Check air flow, fan speed and pressure balance.
- Review alarm logs and any error indications.
- Listen for sounds or vibrations.
- Check operation in different modes (high/low, bypass, etc.).
Troubleshooting and malfunctions
In case of a malfunction, check the following points before contacting customer support:
- No operation: check fuses, power supply, plug.
- Low airflow: check filters, fan motors and belt tension.
- Abnormal sound or vibration: check fasteners, bearings and balance.
- Error indication from sensors: check the cable, sensor and connections.
- Control system failure: check communication and parameters.
Documentation and spare parts
All service measures must be documented in a service log with the date, signature and measures taken. Only use original spare parts and original filters to maintain the warranty.
Filters, fans and other components can be ordered at www.acetec.se
Technical Data Sheet
| Specification | Value |
|---|---|
| Terms and conditions of guarantee | AG20 |
| EC | Yes |
| EcoDesign | Yes |
| EuroVent | Yes |
| Control equipment | EvoControl MPO |
| Cloud service | Yes |
| Flow range (l/s) | 15 - 70 |
| Suitable up to living space (m²) | 120 |
| Connection options | Top |
| Customisable H/V | Yes |
| Placement | Wall |
| Installation in a cold room | No, it is not. |
| Duct connection (mm) | 4 × 125, 1 × 125 |
| Type of heat exchanger | Rotating |
| Power, fan, nom (W) | 2 × 85 |
| Electric battery power, nom (W) | 200 - 800 |
| Connection voltage (V) | 1 × 230 |
| Hedging (A) | 10 |
| IP class | IP21 |
| Built-in electric battery EV | Yes |
| Electric battery kit EV (accessory) | No, it is not. |
| Electric battery kit FV (accessory) | Yes |
| Cooker hood (accessory) | Yes |
| W x H x D (mm) | 599 / 532 / 335 |
| Weight (kg) | 39 |
| Filter class | F5 |
| Coatings / Materials | Magnelis |
| Energy class | A |