EvoAir A390T G2 is a top-connected, compact FTX unit developed for offices, schools and other business premises. The unit is equipped with rotary heat exchangers and radial fans with energy-efficient EC motors and comes as standard with a built-in electric battery, with the option of a water battery.
Brochure
Advantages of the programme
- For offices, schools and business premises
- Top-connected channels
- Rotary heat exchanger
- Radial fans with EC motors
- Filter class ePM1 55 %
- Configurable right/left connection
Full product information is available at www.acetec.se

EvoAir ventilation units are manufactured and quality assured in Älvsbyn, Sweden.
Technical data
| Specification | Value |
|---|---|
| Connection options | Top |
| Flow range (l/s) | 80 to 350 |
| Customisable H/V | Yes |
| Control equipment | EvoControl Touch |
| Type of heat exchanger | Rotating |
| Placement | Floor |
| W x H x D (mm) | 955 / 785 / 715 |
| Weight (kg) | 97,4 |
| Duct connection (mm) | 4 x 250 |
| Power electric battery, built-in (W) | 1700 - 3700 |
| Fan power (W) | 2 x 507 |
| Connection voltage (V) | 1 x 230 |
For technical advice or to request a quote, please contact sales@acetec.se
Pressure and flow diagrams
Channel connections and product dimensions

| Designation | Dimensions (mm) |
|---|---|
| A | 635 |
| B | 160 |
| C | 225 |
| D | 330 |
| E | 160 |
| F | 715 |
| G | 955 |
| H | 785 |
See designations in the illustration above.
Installation Instructions
General
Installation and commissioning shall be carried out by qualified personnel with the necessary professional knowledge to ensure correct operation.
Suitable locations are technical rooms, fan rooms, storage rooms or similar. The unit can also be placed in cold rooms.

Minimum service space in front of inspection hatch:
- A110T: 450 mm
- A170T: 600 mm
- A230T / A390T: 700 mm
Placement

A110T mounted on the wall using the supplied suspension bracket.

A170T-A390T are fitted with a floor stand (100 mm) and placed on the floor.
Reversible for right/left-hand operation
The unit is always supplied in a right-hand version. A left-hand version is available by moving the electric battery cassette to the left-hand fan side. The cassette can be easily removed without tools and no electrical reconnection is required. The temperature sensors are located on top of the unit on delivery and must be installed in the respective duct.
The sensors are labelled and already electrically connected to the unit's control equipment.
Check or change parameter 100 if necessary.
Commissioning
When commissioning, air flows must be adjusted so that the exhaust air flow is 10-15% higher than the supply air flow (negative pressure) for safe operation. Applies to all operating modes.
Important to consider when installing
- Installation and commissioning shall be carried out by a person with sufficient professional knowledge to ensure proper functioning.
- If the system is not commissioned immediately, all duct connections should be sealed inside the unit to prevent moist or cold air from entering and causing moisture damage.
- All operating modes shall be adjusted (Spruce, Comfort and convenience and Forcing).
- The control panel should be positioned so that the user has good access and overview in the event of an alarm.
- The user/manager of the installation shall be informed of the location of the control panel and its functions.
- The installer shall hand over the manuals and the guarantee certificate to the user/manager of the installation.
- The product must be registered at www.acetec.se for the guarantee to apply.
- Original filters must be used during the warranty period for the warranty to be valid.
EvoControl Touch
Control is via a 4.3-inch colour panel with touch display, providing a clear and intuitive user experience. The system has a wired network connection for stable communication and also offers a cloud solution with a responsive design that automatically adapts to mobile phones, tablets or computers. Advanced functionality allows you to control the indoor climate with high precision, customise operation as needed and monitor the system in real time.
Components
EvoControl Touch consists of the following parts:
Display

Main card

- Fuse 5x20mm, 200mAT, 230VAC
- RJ45 network socket
- Battery CR3225
- USB connector
Included
- 15 m cable 4×0.25 mm² (max. length 50 m)
- 4 plastic spacers
- Screw (for surface mounting)
Installation of the display
The touch panel should be installed in a warm, weather-protected and dry area where it is clearly visible and easily accessible to the user. Avoid placing it in areas with high humidity or risk of condensation.
- Push the frame away from the display by holding the edges of the frame and pressing lightly on the display.
- Unscrew the four screws on the sides of the display.
- Fit the wall plate over any existing wall socket or on the outside using plastic spacers and screws.
- Connect the cable to the terminal block on the display.
- Cables can be released from the connector by inserting an object (e.g. a small needle) into the gap above the cable.
- Check that the cables are securely connected and that no strands are sticking out!
Would you like a more detailed description with pictures? Click on the link or scan the QR code at the top. See section 6.
EvoControl Touch display menu
Menu 1

- Heat recovery active / Reheating active / Cooling active / Defrosting active
- Temperature setting for active operating mode
- Activation of operating mode
- Indication of external operating mode, air quality control, fire, stop
- Various alarms (see alarms in technical manual), cloud service, network
- Go to Menu 2
- Activation of ECO function (parameter 400 must be activated)
- Activation of sleep mode (times must be set); to deactivate, press and hold the button for 2 seconds.
- Activation of overpressure function (fireplace function)
- Activation of forced hours
- Stop active, to activate hold button for 2 seconds / Other operating mode active or unit in standby (timer, external control)
Menu 2

- Display of measurement values in real time
- Time menu
- Alarm acknowledgement and history
- Service menu. PIN code 1 required
- Settings menu. PIN code 1 for normal settings and PIN code 2 for advanced settings required.
- System information
Quick guide to EvoControl Touch
Step 1)
Press the button Menu button:
Step 2)
Press the button Preferences:
Step 3)
Enter the authorisation code 6374 for basic settings or 8990 for advanced settings and press Enter.
Step 4)
Press the button Fan:
Step 5)
- Use the arrow keys to navigate to the parameters you want to change.
- Use minus and plus to change the value.
- Save the value with the button Save (only visible when the value is changed).
- Pressures Back to go back to the start menu.
Wiring Diagram
Operation and Maintenance
Before working with the unit
Only authorised personnel should operate and service the unit. This instruction applies to all units and describes operating principles, maintenance, troubleshooting and safety measures. The aim is to ensure a long service life, high operational reliability and energy-efficient operation.
General about the unit
Service intervals and inspection schedule
Carry out servicing at least twice a year or more often at high load. Supplement with intervals for specific components as below:
- Filter byte: every 3-6 months or after a defined number of operating hours.
- Checking seals and mouldings: each service.
- Checking fan bearings and motors: annually.
- Cleaning of rotor or heat exchanger: annually.
- Control of sensors and control systems: annually.
See service procedure (cleaning, dismantling, etc.) on the next page.
Service procedure
- Switch off the power to the unit via fuse or plug before servicing.
- Secure the unit against accidental re-connection during work.
- Wait until all moving parts have come to a complete stop before starting work.
- Use personal protective equipment such as protective gloves and goggles. When working with dust, wear a respirator.
- Mark the unit with a warning sign during servicing.
- Open inspection hatches or panels (e.g. loosen screws with a suitable Allen key).
- Take old filters straight out of their mounts.
- Vacuum the inside and clean surfaces with a mild detergent (avoid strong solvents).
- To facilitate internal cleaning, fans fitted with electrical connectors can be removed from the unit (document electrical connections before dismantling components).
- If necessary, clean the rotor or heat exchanger unit according to the recommended method.
- Check seals, gaskets and mouldings.
- Fit new filters and reassemble components correctly. Original filters can be ordered at www.acetec.se
- Check that everything is secure and close the hatches.
- Reinstall all guards and ensure proper operation before putting the unit into service.
After completion of the service
- Reconnect the power.
- Switch on the unit.
- Check air flow, fan speed and pressure balance.
- Review alarm logs and any error indications.
- Listen for sounds or vibrations.
- Check operation in different modes (high/low, bypass, etc.).
Troubleshooting and malfunctions
In case of a malfunction, check the following points before contacting customer support:
- No operation: check fuses, power supply, plug.
- Low airflow: check filters, fan motors and belt tension.
- Abnormal sound or vibration: check fasteners, bearings and balance.
- Error indication from sensors: check the cable, sensor and connections.
- Control system failure: check communication and parameters.
Documentation and spare parts
All service measures must be documented in a service log with the date, signature and measures taken. Only use original spare parts and original filters to maintain the warranty.
Filters, fans and other components can be ordered at www.acetec.se
Technical Data Sheet
| Specification | Value |
|---|---|
| Terms and conditions of guarantee | AG20 |
| EC | Yes |
| EcoDesign | Yes |
| EuroVent | No, it is not. |
| Control equipment | EvoControl Touch |
| Cloud service | Yes |
| Flow range (l/s) | 80 - 350 |
| Cooker hood (accessory) | No, it is not. |
| Connection options | Top |
| Customisable H/V | Yes |
| Placement | Floor |
| Installation in a cold room | Yes |
| Duct connection (mm) | 4 × 250 |
| Type of heat exchanger | Rotating |
| Power, fan, nom (W) | 2 × 507 |
| Electric battery power, nom (W) | 1700 - 3700 |
| Connection voltage (V) | 1 × 230 |
| Hedging (A) | 10 |
| IP class | IP21 |
| Built-in electric battery EV | Yes |
| Electric battery kit EV (accessory) | No, it is not. |
| Electric battery kit FV (accessory) | No, it is not. |
| Water battery kit (accessory) | Yes |
| W x H x D (mm) | 955 / 785 / 715 |
| Weight (kg) | 97,4 |
| Filter class | F7 |
| Coatings / Materials | Magnelis |
| Corrosion class | C4 |